Electrophysiology

Electrophysiology (from Greek ἥλεκτ, ēlektron, "amber" [see the etymology of "electron"]; φύσις, physis, "nature, origin"; and -λογία, -logia) is the branch of physiology that studies the electrical properties of biological cells and tissues.It involves measurements of voltage changes or electric current or manipulations on a wide variety of scales from single ion channel proteins to whole organs like the heart.Depending on the preparation and precise placement, an extracellular configuration may pick up the activity of several nearby cells simultaneously, termed multi-unit recording.Interest in the spatial distribution of bioelectric activity prompted development of molecules capable of emitting light in response to their electrical or chemical environment.To make an intracellular recording, the tip of a fine (sharp) microelectrode must be inserted inside the cell, so that the membrane potential can be measured.In 1963, Alan Lloyd Hodgkin and Andrew Fielding Huxley won the Nobel Prize in Physiology or Medicine for their contribution to understanding the mechanisms underlying the generation of action potentials in neurons.Their experiments involved intracellular recordings from the giant axon of Atlantic squid (Loligo pealei), and were among the first applications of the "voltage clamp" technique.The preparation of these slices is commonly achieved with tools such as the Compresstome vibratome, ensuring optimal conditions for accurate and reliable recordings.[5] Nevertheless, even with the highest standards of tissue handling, slice preparation induces rapid and robust phenotype changes of the brain's major immune cells, microglia, which must be taken into consideration when using this model.Consider this example based on Ohm's law: A voltage of 10 mV is generated by passing 10 nanoamperes of current across 1 MΩ of resistance.Patch-clamp may also be combined with RNA sequencing in a technique known as patch-seq by extracting the cellular contents following recording in order to characterize the electrophysiological properties relationship to gene expression and cell-type.In situations where one wants to record the potential inside the cell membrane with minimal effect on the ionic constitution of the intracellular fluid a sharp electrode can be used.These micropipettes (electrodes) are again like those for patch clamp pulled from glass capillaries, but the pore is much smaller so that there is very little ion exchange between the intracellular fluid and the electrolyte in the pipette.This property allows the application of rapid substrate/ligand concentration jumps to investigate the electrogenic activity of the protein of interest, measured via capacitive coupling between the vesicles and the electrode.[13] The bioelectric recognition assay (BERA) is a novel method for determination of various chemical and biological molecules by measuring changes in the membrane potential of cells immobilized in a gel matrix.BERA is the core technology behind the recently launched pan-European FOODSCAN project, about pesticide and food risk assessment in Europe.The method has also been used for the detection of environmental toxins, such as pesticides[17][18][19] and mycotoxins[20] in food, and 2,4,6-trichloroanisole in cork and wine,[21][22] as well as the determination of very low concentrations of the superoxide anion in clinical samples.[23][24] A BERA sensor has two parts: A recent advance is the development of a technique called molecular identification through membrane engineering (MIME).While atomistic simulations may access timescales close to, or into the microsecond domain, this is still several orders of magnitude lower than even the resolution of experimental methods such as patch-clamping.Scientists such as Duchenne de Boulogne (1806–1875) and Nathaniel A. Buchwald (1924–2006) are considered to have greatly advanced the field of neurophysiology, enabling its clinical applications.In practice a MINI module comprises a checklist of information that should be provided (for example about the protocols employed) when a data set is described for publication.
"Current Clamp" is a common technique in electrophysiology. This is a whole-cell current clamp recording of a neuron firing due to its being depolarized by current injection
The voltage clamp uses a negative feedback mechanism. The membrane potential amplifier measures membrane voltage and sends output to the feedback amplifier. The feedback amplifier subtracts the membrane voltage from the command voltage, which it receives from the signal generator. This signal is amplified and returned into the cell via the recording electrode.
The cell-attached patch clamp uses a micropipette attached to the cell membrane to allow recording from a single ion channel.
A schematic diagram showing a field potential recording from rat hippocampus. At the left is a schematic diagram of a presynaptic terminal and postsynaptic neuron. This is meant to represent a large population of synapses and neurons. When the synapse releases glutamate onto the postsynaptic cell, it opens ionotropic glutamate receptor channels. The net flow of current is inward, so a current sink is generated. A nearby electrode (#2) detects this as a negativity. An intracellular electrode placed inside the cell body (#1) records the change in membrane potential that the incoming current causes.
-logiaphysiologyvoltageelectric currention channelproteinsneuroscienceneuronsaction potentialnervous systemelectroencephalographyelectrodiagnosismonitoringion currentelectrodespotassium chlorideintracellularpatch recordingaction potentialssingle-unit recordingmulti-unit recordinglocal field potentialssingle channel recordingamperometrysenseselectrophotographycombining formdiagnosticelectrodiagnostic testingelectrocardiographycardiac muscleatrialventricularcerebral cortexelectrocorticographyelectromyographymusclesskeletalsmoothelectrooculographyelectroretinographyretinaelectronystagmographyelectroolfactographyolfactory epitheliumelectroantennographyolfactory receptorselectrocochleographycochleaelectrogastrographystomachelectrogastroenterographyelectroglottographyglottiselectropalatographypalatalarterialeyelidpancreasuteruselectroneuronographynervesspinal cordvomeronasal organvoltage sensitive dyesmembrane potentialAlan Lloyd HodgkinAndrew Fielding Huxleygiant axonelectrical resistanceslice preparationmicrogliaVoltage clampcell potentialion channelsvoltage-gated ion channelsCurrent clampneurotransmitterselectrometerimpedancenanoamperesvoltage followerresistorpatch clampErwin NeherBert Sakmannpatch-seqLucifer yellowDavid HubelTorsten Wieselvisual cortexspike sortingpresynaptic terminalExtracellular field potentialssimultaneous activationsynaptic transmissionglutamate receptorslocal field potentialnorepinephrinedopamineserotoninmicrofluidicsscanning probePerfusionborosilicateliposomesvesicleschromiummercaptanecapacitivebiosensor applicationsimmobilized cellshepatitis Bherpesfoot and mouth diseaseprionsblue tongue viruspesticidesmycotoxins2,4,6-trichloroanisolesuperoxideartificial intelligencein silicomolecular dynamicslipid bilayerelectroporationClinical electrophysiologyclinical cardiac electrophysiologyarrhythmiaclinical neurophysiologyDuchenne de BoulogneNathaniel A. BuchwaldneurophysiologyMinimum Information (MI) standardsmeta dataAutomated patch clampBioelectrochemistryBioelectromagneticsCardiac electrophysiologyElectrophysiology studyHille equationHistory of bioelectricityMultiscale Electrophysiology FormatTranscutaneous electrical nerve stimulationBibcodeWayback MachineFish physiologyHuman physiologyInsect physiologyPhysiology of dinosaursPlant physiologyPlant perception (physiology)Physiological plant disordersCell physiologyComparative physiologyEcophysiologyEvolutionary physiologyMolecular physiology